Liem Grey Nature 47″ X 47″
Ceramic
Description
Artisan (by sq. ft.) Marble effect floor tile in grey. Size 47 x 47 in.
Features
Tile with a high degree of compaction, uniform in appearance and with a lower percentage of glazing in the composition. Nature. General deshaded design with a degree of color and appearance variation. Name given to the finish of those tiles dimensionally improved after the firing process. Installation on floor.
Colors
Thickness
1/4″ approx.
Size
47 1/4″ approx.
x 47 1/4″ approx.
Finish
Nature
Shape
Square
Edge Detail
Rectified
Testing
Breaking Strength | Chemical Resistance | Stain Resistance | Resistance to thermal shock | Water Absorption | Crazing Resistance | Modulus of Rupture | Shade Variation Rating |
1118.5 N | MÍNIMO CLASE B | Class 5. | Resiste | BIa – Porcelanico (E<=0.1%) | Resists 3 cycles | 43.6 N/mm2 | V3 |
ANTI-SLIP VALUE
Dynamic coefficient of friction (dcof) 0.67 (T-8C2)
Slip resistance (wet pendulum) irhd 55 CL1
Pendulum test value (ptv) irhd 96 WET-28 / DRY-66 (T-8C2)
Slip resistance (pendulum-dry) >40**
Determination of light reflectance value (lrv) = 16.41
Packing
Sales units per box 31 SQF/CS
Sales units per pallet 868.06 SQF/PAL
Sales units per unit 15.5 SQF/ST
Recommended Use Locations
Single-family dwelling
Outdoor Premises: Porches, verandah, terrace, outdoor access or circulation area
Indoor Premises – Dry: Entrance and other enclosures with direct opening to the outside (garden, terrace, storage room).
Indoor Premises – Dry: Individual staircase
Indoor Premises – Wet: Kitchen, mini kitchen in living area, laundry room
Indoor Premises – Humid: Bathroom or Toilet
Collective housing
Outdoor premises: Balconies, terraces, galleries (not accessible from the outside)
Indoor Premises – Common Elements: Stairs and corridors with or without lifts
Indoor Premises – Common Elements: Meter centralisation room
Indoor Premises – Common Elements: Storage rooms for children’s cars, bicycles, etc.
Indoor Premises – Dwelling – Damp: Kitchen, mini kitchen and living area, laundry room
Indoor Premises – Dwelling – Damp: Bathrooms or shower rooms
Public Residential
Single or double rooms
Group rooms
Intensive use dormitories in residences, schools, etc.
Administrative
Office with workstation
Collective office, open plan office
Meeting/conference room, shops and retail (sales area)
Commercial
Shops and retail trade (Sales area)
Teacher
Pre-school and Primary: Classroom without direct opening to the exterior
Infant and Primary: Playroom, exercise, multi-purpose room without direct opening to the outside.
Secondary, Baccalaureate and University: Other laboratories (physics, electricity, radiation, mechanics).
Sanitary
Single-user room, isolation room
Collective room
Major and minor operating theatres. Operating theatres
Radiological premises
Rehabilitation, massage, therapy and rehabilitation centres
Laboratories (no public access)
Public attendance
Catering: Dining room, company cafeteria
Libraries and reading rooms: Libraries, reading rooms, houses of worship, museums (Internal use)
Service, facilities
Toilets in office areas, restricted use
Sanitary premises special hygiene (hospitals, food)
Premises for telephone, computer and other dry installations